Titan Innova Series
High Power Double Conversion Online UPS 1KVA - 20KVA
Titan Innova Series
Features

Features

  • DSP Microprocessor controlled UPS
  • True online Double Conversion Sinewave UPS
  • High input power factor > 0.99
  • High performance with high efficiency
  • LCD display and audible alarm
  • Transformer-less design reduce footprints
  • N+X (4x) parallel redundant and capacity expansion for 6K to 20K
  • Full communication interface connectivity - USB, RS232, dry contact, EPO & intelligent slot
  • Built-in maintenance bypass for 6KVA UPS onwards
  • Extended backup time capability (KS model)
Titan Innova 1K/KS
Capacity 1000VA/800W
Input
Nominal 230 VAC
Voltage Range 110-300 VAC
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99
Output
Nominal 220/208/220/230/240 VAC
Regulation +/- 2%
Translent Response < 10%
Crest Factor 3:1
Harmonic Distortion < 4% THD (Linear load)
< 6% (Non-linear load)
Overload (Line Mode) < 125% for 5mins, < 150% for 30sec
> 150% for 0.5 sec to bypass/shutdown (inverter)
Output Waveform Pure Sinewave
Efficiency
AC Mode >85%
Batt. Mode >83%
ECO Mode >97%
Battery - Standard Model
Battery Type 12V 7AH
Quantity 3
Typical Recharge Time < 5 hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 36.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 3
Charging Current (max.) 8A
Charging Voltage 36.0 VDC
Titan Innova 2K/KS & 3K/KS
Capacity 2000VA/1600W & 3000VA/2400W
Input
Nominal 230 VAC
Voltage Range 110-300 VAC
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99
Output
Nominal 200/208/220/230/240 VAC
Regulation +/- 2%
Translent Response < 10%
Crest Factor 3:1
Harmonic Distortion < 4% THD (Linear load)
< 7% (Non-linear load)
Overload (Line Mode) < 125% for 5mins, < 150% for 30sec
> 150% for 0.5 sec to bypass/shutdown (inverter)
Output Waveform Pure Sinewave
Efficiency
AC Mode >86%
Batt. Mode >83%
ECO Mode >97%
Battery - Standard Model
Battery Type 12V 7AH
Quantity 8
Typical Recharge Time < 5 hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 96.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 8
Charging Current (max.) 8A
Charging Voltage 96.0 VDC
Titan Innova 6K/KS
Capacity 6000VA/5400W
Input
Nominal 230 VAC
Voltage Range 176-276 VAC
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99
Output
Nominal 208/220/230/240 VAC
Regulation +/- 2%
Translent Response < 9% (for 0-100% -0% R)
Crest Factor 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% (Non-linear load)
Overload (Line Mode) < 125% for 2mins, < 150% for 30sec
> 150% for 1.0 sec to bypass
Output Waveform Pure Sinewave
Efficiency
AC Mode >92%
Batt. Mode >92%
ECO Mode >97%
Battery - Standard Model
Battery Type 12V 7AH
Quantity 20
Typical Recharge Time < 5 hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 240.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20
Charging Current (max.) 4A
Charging Voltage 240.0 VDC
Titan Innova 10K/KS
Capacity 10000VA/9000W
Input
Nominal 230 VAC
Voltage Range 176-276 VAC
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99
Output
Nominal 208/220/230/240 VAC
Regulation < 1%
Translent Response < 9% (for 0-100% -0% R)
Crest Factor 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% (Non-linear load)
Overload (Line Mode) < 125% for 2mins, < 150% for 30sec
> 150% for 1.0 sec to bypass
Output Waveform Pure Sinewave
Efficiency
AC Mode >92%
Batt. Mode >92%
ECO Mode >97%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20
Typical Recharge Time < 5 hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 240.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20
Charging Current (max.) 4A
Charging Voltage 240.0 VDC
Titan Innova 3C10K/KS
Capacity 10000VA/9000W
Input
Nominal 230 VAC
Voltage Range 110-276 VAC for single phase input
190-478 VAC for three phase input
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99 @ 100% load
Output
Nominal 200/208/220/230/240 VAC
Regulation < 1%
Translent Response < 7% (for 0-100% -0% R)
Crest Factor 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% (Non-linear load)
Overload (Line Mode) < 5mins @ 100%-110% / 1min @ 110% 130%
(backup mode -10s @ 130%-150% /2s @ > 150%)
Output Waveform Pure Sinewave
Efficiency
AC Mode >94% @ full load and battery fully charged
Batt. Mode >93% @ full load (12 VDC battery)
ECO Mode >98% @ full load and battery fully charged
Battery - Standard Model
Battery Type 12V 7AH
Quantity 24pcs x 2 strings
Typical Recharge Time < 3 hours recover to 90% capacity
Charging Current (max.) 4A
Charging Voltage 288.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 24pcs
Charging Current (max.) 4A
Charging Voltage 288.0 VDC
Titan Innova 3C20K/KS
Capacity 20000VA/18000W
Input
Nominal 230 VAC
Voltage Range 110-276 VAC for single phase input
190-478 VAC for three phase input
Frequency Range 45Hz~55Hz or 54Hz~66Hz
Power Factor >0.99 @ 100% load
Output
Nominal 200/208/220/230/240 VAC
Regulation < 1%
Translent Response < 7% (for 0-100% -0% R)
Crest Factor 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% (Non-linear load)
Overload (Line Mode) < 5mins @ 100%-110% / 1min @ 110% 130%
(backup mode -10s @ 130%-150% /2s @ > 150%)
Output Waveform Pure Sinewave
Efficiency
AC Mode >94% @ full load and battery fully charged
Batt. Mode >93% @ full load (12 VDC battery)
ECO Mode >98% @ full load and battery fully charged
Battery - Standard Model
Battery Type 12V 9AH
Quantity 24pcs x 2 strings
Typical Recharge Time < 3 hours recover to 90% capacity
Charging Current (max.) 4A
Charging Voltage 288.0 VDC
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 24pcs
Charging Current (max.) 4A
Charging Voltage 288.0 VDC

Technical specifications are subject to change without notice.