Preloader
Galleon Pro III 3P Rackmount Series
Online Double Conversion UPS 10KVA/KW- 60KVA/KW
Galleon Pro Rackmount Series
Features

Features

  • True Online Double Conversion Sinewave UPS
  • DSP technology guarantees high performances
  • Output power factor = 1.0
  • Active power factor correction for all input phases
  • 50Hz/60Hz frequency convert mode
  • ECO mode operation for energy saving
  • 3.5” LCD colour Touch Screen with Auto rotation and Mimic Flow for 10K-30K
  • LCD display for comprehensive UPS information for 40K-60K
  • Adjustable battery quantities design
  • Dual input for flexible configuration
  • 3-stage charging design to optimized battery performance
  • Parallel operation up to 4 units with common battery system
  • Power walk-in function
  • Generator Compatible
Galleon Pro III Rackmount 10KRS
Phase 1 Phase in / 1Phase out;
3 Phase in / 1 Phase out;
3 Phase in / 3 Phase out
Capacity 10kVA / 10kW
Input
Nominal Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 20 (10+10) pcs
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-12A (Adjustable)
Charging Voltage ± 13.65V x N (N=10)
Galleon Pro III Rackmount 15KRS
Phase 1 Phase in / 1Phase out;
3 Phase in / 1 Phase out;
3 Phase in / 3 Phase out
Capacity 15kVA / 15kW
Input
Nominal Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 32 (16+16 pcs) ~ 40 (20+20 pcs) Adjustable
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-12A (Adjustable)
Charging Voltage ± 13.65V x N (N=16~20)
Galleon Pro III Rackmount 20KRS
Phase 1 Phase in / 1Phase out;
3 Phase in / 1 Phase out;
3 Phase in / 3 Phase out
Capacity 20kVA / 20kW
Input
Nominal Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 32 (16+16 pcs) ~ 40 (20+20 pcs) Adjustable
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-12A (Adjustable)
Charging Voltage ± 13.65V x N (N=16~20)
Galleon Pro III Rackmount 30KRS
Phase 3 Phase in / 3 Phase out
Capacity 30kVA / 30kW
Input
Nominal Voltage Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage One Phase 220 / 230 / 240V (2 wires, 1 Ph + N + E)
Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 32 (16+16 pcs) ~ 40 (20+20 pcs) Adjustable
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-12A (Adjustable)
Charging Voltage ± 13.65V x N (N=16~20)
Galleon Pro III Rackmount 40KRS
Phase 1 Phase in / 1Phase out;
3 Phase in / 1 Phase out;
3 Phase in / 3 Phase out
Capacity 40kVA / 40kW
Input
Nominal Voltage Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 32 (16+16 pcs) ~ 40 (20+20 pcs) Adjustable
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-16A (Adjustable)
Charging Voltage ± 13.65V x N (N=16~20)
Galleon Pro III Rackmount 60KRS
Phase 3 Phase in / 3 Phase out
Capacity 60kVA / 60kW
Input
Nominal Voltage Three Phase 3 x 380 / 400 / 415V (4Wires, 3phases + N + E)
Voltage Range 190-520 VAC (3-Phase) at 50% load
305-478 VAC (3-Phase) at 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor ≥ 0.99 @ 100% load
Total Current Harmonic Distortion (THDi) < 4% at full load
Output
Output Voltage Three Phase 3 x 360* / 380 / 400 / 415V (4Wires, 3phases + N + E)
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 46Hz~54Hz ± 1% or 56~64Hz ± 1%
Current Crest Ratio 3:1 (max)
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Overload (AC mode) 100-110% for 60mins; 111-125% for 10mins,
126-150% for 1min; >150% immediately
Efficiency
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
Battery - Standard Model
Battery Type 12V, Sealed Lead Acid Maintenance Free (SLA)
Quantity 32 (16+16 pcs) ~ 40 (20+20 pcs) Adjustable
Typical Recharge Time Depending on the capacity of external batteries
Charging Current (max.) 1A-18A (Adjustable)
Charging Voltage ± 13.65V x N (N=16~20)

Technical specifications are subject to change without notice.