Preloader
Galleon Pro 3P/1P Series
3 Phase In / Single Phase Out
Double Conversion On-line Parallel System form 10KVA to 30KVA
Galleon Pro 3P/1P Series
Features

Features

  • True double-conversion sinewave UPS
  • DSP technology guarantees high performance
  • Output power factor up to 0.9
  • Wide input voltage range (110-300 VAC)
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Programmable power management outles
  • Emergency Power Off (EPO) feature available
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery quantities
  • Built-in maintenance bypass
  • N+X parallel redundancy
Galleon Pro 3C10K/10KS
Capacity 10000VA / 9000W
Phase 3 phase in / 1 phase out
Form Factor Tower
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 90.5%
Battery Mode 86%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 8A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C10KR/10KRS
Capacity 10000VA / 9000W
Phase 3 phase in / 1 phase out
Form Factor Rackmount
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 90.5%
Battery Mode 87%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 4A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C15K/15KS
Capacity 15000VA / 13500W
Phase 3 phase in / 1 phase out
Form Factor Tower
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91%
Battery Mode 88%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs x 2 strings
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 8A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C15KR/15KRS
Capacity 15000VA / 12000W
Phase 3 phase in / 1 phase out
Form Factor Rackmount
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91%
Battery Mode 88%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs x 2 strings
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 4A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C20K/20KS
Capacity 20000VA / 18000W
Phase 3 phase in / 1 phase out
Form Factor Tower
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91%
Battery Mode 87%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs x 2 strings
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 8A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C20KR/20KRS
Capacity 20000VA / 18000W
Phase 3 phase in / 1 phase out
Form Factor Rackmount
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91%
Battery Mode 87%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs x 2 strings
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 4A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)
Galleon Pro 3C30K/30KS
Capacity 30000VA / 27000W
Phase 3 phase in / 1 phase out
Form Factor Tower
Input
Nominal Voltage 3 x 400 VAC (3Ph + N)
Voltage Range 195-520 VAC (3 Phase) @ 50% load
305-478 VAC (3 Phase) @ 100% load
Frequency Range 46Hz~54Hz or 56Hz~64Hz
Power Factor >0.99 @ 100% load
THDi ≤ 6% @ 100% load
Output
Nominal Voltage 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear load)
< 5% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91.3%
Battery Mode 87%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20pcs x 3 strings
Typical Recharge Time 9 Hours recover to 90% capacity
Charging Current (max.) 4A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on applications
Quantity 20pcs (adjustable)
Charging Current (max.) 12A
Charging Voltage 273.0 VDC ± 1% (based on 20pcs batteries)