Galleon Pro Rackmount Series
Double Conversion On-line Parallel System form 1KVA to 10KVA
Galleon Pro Rackmount Series
Features

Features

  • True double-conversion Sinewave UPS
  • Wide input voltage range (110-300 VAC)
  • Input power factor correction 0.99
  • Output power factor 0.9
  • Fault Tolerance Design with Parallel capability
  • Field Upgradable to 10KVA - 30KVA (N+X) design
  • Hotswappable Battery system and intelligent Battery management
  • 50Hz/60Hz Frequency Converter Mode
  • Programmable power management outlets
  • Emergency Power Off Function(EPO)
  • ECO mode operation for energy saving (ECO)
  • Charger capacity expansion to 8A for extended runtime model
  • USB/RS232/SNMP multiple communications
  • Smart battery charger design for optimized battery performance
  • Selectable output voltage via LCD control panel
Galleon Pro 1KR/1KRS
Phase Single phase with ground
Capacity 1000VA / 900W
Input
Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC
Voltage Range 55-150 VAC ± 5% or 100-300 VAC ± 5% @ 50% load
80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load
Frequency Range 40Hz - 70Hz
Power Factor >0.99 @ Nominal VOltage (100% load)
THDi < 5% @ 100 ~ 130 VAC or 205 -245 VAC
Output
AC Voltage Regulation (Batt. Mode) 200 / 208 / 220 / 230 / 240 VAC ± 1%
Frequency Range (Sync. Range) 57Hz~63Hz or 47~53Hz
Frequency Range (Batt. Mode) 60Hz ± 0.1Hz or 50Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 8% max. (Batt. mode before shut down)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms (Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 86%
Battery Mode 83%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 2
Typical Recharge Time 4 Hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 27.4 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on the capacity of external batteries
Quantity 2
Charging Current (max.) 1A/2A/4A/8A (Selectable via LCD)
Charging Voltage 27.4 ± 1%
Galleon Pro 2KR/2KRS
Phase Single phase with ground
Capacity 2000VA / 1800W
Input
Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC
Voltage Range 55-150 VAC ± 5% or 100-300 VAC ± 5% @ 50% load
80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load
Frequency Range 40Hz - 70Hz
Power Factor >0.99 @ Nominal VOltage (100% load)
THDi < 5% @ 100 ~ 130 VAC or 205 -245 VAC
Output
Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC ± 1%
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 57Hz~63Hz or 47~53Hz
Frequency Range (Batt. Mode) 60Hz ± 0.1Hz or 50Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 8% max. (Batt. mode before shut down)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms (Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 88%
Battery Mode 85%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 4
Typical Recharge Time 4 Hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 54.8 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on the capacity of external batteries
Quantity 4
Charging Current (max.) 1A/2A/4A/8A (Selectable via LCD)/td>
Charging Voltage 54.8 VDC ± 1%
Galleon Pro 3KR/3KRS
Phase Single phase with ground
Capacity 3000VA / 2700W
Input
Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC
Voltage Range 55-150 VAC ± 5% or 100-300 VAC ± 5% @ 50% load
80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load
Frequency Range 40Hz - 70Hz
Power Factor >0.99 @ Nominal VOltage (100% load)
THDi < 5% @ 100 ~ 130 VAC or 205 -245 VAC
Output
Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC ± 1%
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Sync. Range) 57Hz~63Hz or 47~53Hz
Frequency Range (Batt. Mode) 60Hz ± 0.1Hz or 50Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 8% max. (Batt. mode before shut down)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms (Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 88%
Battery Mode 85%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 6
Typical Recharge Time 4 Hours recover to 90% capacity
Charging Current (max.) 1A
Charging Voltage 82.1 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on the capacity of external batteries
Quantity 6
Charging Current (max.) 1A/2A/4A/8A (Selectable via LCD)
Charging Voltage 82.1 VDC ± 1%
Galleon Pro 6KR/6KRS
Phase Single phase with ground
Capacity 6000VA / 6000W
Input
Nominal Voltage 208 / 220 / 230 / 240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
176-300 VAC ± 3% @ 100% load
Frequency Range 46Hz - 54Hz or 56Hz - 64Hz or 60Hz
Power Factor >0.99 @ Nominal Voltage (100% load)
THDi < 4% @ 205 -245 VAC
Output
AC Voltage Regulation (Batt. Mode) 208 / 220 / 230 / 240 VAC ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 50Hz / 56Hz~64Hz or 60Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 3% THD (Linear load)
< 6% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 89%
Battery Mode 88%
Battery - Standard Model
Battery Type 12V 7AH
Quantity 20
Typical Recharge Time 3 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on the capacity of external batteries
Quantity 18-20
Charging Current (max.) 2A
Charging Voltage 273.0 ± 1%
Galleon Pro 10KR/10KRS
Phase Single phase with ground
Capacity 10000VA / 10000W
Input
Nominal Voltage 208 / 220 / 230 / 240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
176-300 VAC ± 3% @ 100% load
Frequency Range 46Hz - 54Hz or 50Hz / 56Hz - 64Hz or 60Hz
Power Factor >0.99 @ Nominal Voltage (100% load)
THDi < 5% @ 205 -245 VAC
Output
AC Voltage Regulation (Batt. Mode) 208 /220 / 230 / 240 VAC ± 1%
Frequency Range (Sync. Range) 46Hz~54Hz or 50Hz / 56Hz~64Hz or 60Hz
Frequency Range (Batt. Mode) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 3% THD (Linear load)
< 6% THD (Non-linear load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 89%
Battery Mode 88%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 20
Typical Recharge Time 4 Hours recover to 90% capacity
Charging Current (max.) 2A
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on the capacity of external batteries
Quantity 18-20
Charging Current (max.) 2A
Charging Voltage 273.0 ± 1%

Technical specifications are subject to change without notice.