Preloader
Galleon One RT Series
Online Double Conversion UPS 1KVA/KW- 10KVA/KW
Galleon Pro Rackmount Series
Features

Features

  • True Online Double Conversion Sinewave UPS
  • Output power factor 1
  • Output voltage regulation <1%
  • 50Hz/60 Hz frequency converter mode
  • Programmable power management outlets
  • Hot swappable battery design
  • ECO mode energy saving
  • Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection
  • High power factor charge up to 12A for 1-3kVA capacity with very low ripple current when charging battery
  • Low input THDi to reduce power system pollution
  • Adjustable charging current via LCD panel
  • Optional HID power device USB port
Galleon One RT 1K / 1KS
Phase Single phase with ground
Capacity 1000VA / 1000W
Input
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
160-300 VAC ± 3% @ 100% load
Frequency Range 40Hz~70Hz
Power Factor ≥ 0.99 @ Nominal Voltage @ 100% load
Total Current Harmonic Distortion (THDi) ≤ 5% at nominal input voltage
Output
Output Voltage 200/208/220/230/240 VAC
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 47Hz ~ 53Hz or 57~63Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1Hz or 60 Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion Linear Load: THD ≤2%,
Non-Linear Load : THD ≤4%
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms(Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode ≥ 89%
Battery Mode ≥ 88%
Battery - Standard Model
Battery Type 12V9AH
Quantity 2
Typical Recharge Time 3 hours recover to 95% capacity for internal battery
at 2A charging current
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 27.4 Vdc ±1%
Battery - Extended Runtime Model
Battery Capacity Depending on the capacity of external batteries
Quantity 2
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 27.4 Vdc ±1%
Galleon One RT 2K / 2KS
Phase Single phase with ground
Capacity 2000VA / 2000W
Input
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
160-300 VAC ± 3% @ 100% load
Frequency Range 40Hz~70Hz
Power Factor ≥ 0.99 @ Nominal Voltage @ 100% load
Total Current Harmonic Distortion (THDi) ≤ 5% at nominal input voltage
Output
Output Voltage 200/208/220/230/240 VAC
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 47Hz ~ 53Hz or 57~63Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1Hz or 60 Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion Linear Load: THD ≤2%,
Non-Linear Load : THD ≤4%
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms(Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode ≥ 91%
Battery Mode ≥ 90%
Battery - Standard Model
Battery Type 12V9AH
Quantity 4
Typical Recharge Time 3 hours recover to 95% capacity for internal battery
at 2A charging current
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 54.8 Vdc ±1%
Battery - Extended Runtime Model
Battery Capacity Depending on the capacity of external batteries
Quantity 4
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 54.8 Vdc ±1%
Galleon One RT (3K / 3KS)
Phase Single phase with ground
Capacity 3000VA / 3000W
Input
Nominal Voltage 200/208/220/230/240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
160-300 VAC ± 3% @ 100% load
Frequency Range 40Hz~70Hz
Power Factor ≥ 0.99 @ Nominal Voltage @ 100% load
Total Current Harmonic Distortion (THDi) ≤ 5% at nominal input voltage
Output
Output Voltage 200/208/220/230/240 VAC
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 47Hz ~ 53Hz or 57~63Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1Hz or 60 Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion Linear Load: THD ≤2%,
Non-Linear Load : THD ≤4%
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 4ms(Typical)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode ≥ 91%
Battery Mode ≥ 90%
Battery - Standard Model
Battery Type 12V9AH
Quantity 6
Typical Recharge Time 3 hours recover to 95% capacity for internal battery
at 2A charging current
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 82.1 Vdc ±1%
Battery - Extended Runtime Model
Battery Capacity Depending on the capacity of external batteries
Quantity 6
Typical Recharge Time 3 hours recover to 95% capacity for internal battery
at 2A charging current
Charging Current (max.) 2A - 12A (Adjustable)
Charging Voltage 82.1 Vdc ±1%
Galleon One RT 6K/6KS
Phase Single phase with ground
Capacity 6000VA / 6000W
Input
Nominal Voltage 208/220/230/240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
176-300 VAC ± 3% @ 100% load
Frequency Range 46Hz - 54Hz or 56Hz - 64Hz
Power Factor ≥ 0.99 @ full load
Total Current Harmonic Distortion (THDi) < 4% @ 100% load; < 6% @ 50% load
Output
Output Voltage 208/220/230/240 VAC
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46 ~ 54 Hz or 56 ~ 64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1Hz or 60 Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 3% THD (Linear Load)
< 6% THD (Non-linear Load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode ≥ 94%
Battery Mode ≥ 92%
Battery - Standard Model
Battery Type 12V7AH
Quantity 20
Typical Recharge Time 7 Hours recover to 90% capacity
Charging Current (max.) 1A - 4A (Adjustable)
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Capacity Depending on the capacity of external batteries
Quantity 16-20
Charging Current (max.) 2A – 12A (Adjustable)
Charging Voltage (13.65 x battery number) Vdc ±1%
Galleon One RT 10K/10KS
Phase Single phase with ground
Capacity 10,000VA / 10,000W
Input
Nominal Voltage 208/220/230/240 VAC
Voltage Range 110-300 VAC ± 3% @ 50% load
176-300 VAC ± 3% @ 100% load
Frequency Range 46Hz - 54Hz or 56Hz - 64Hz
Power Factor ≥ 0.99 @ full load
Total Current Harmonic Distortion (THDi) < 4% @ 100% load; < 6% @ 50% load
Output
Output Voltage 208/220/230/240 VAC
AC Voltage Regulation
(Batt. Mode)
± 1%
Frequency Range (Sync. Range) 46 ~ 54 Hz or 56 ~ 64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1Hz or 60 Hz ± 0.1Hz
Current Crest Ratio 3:1
Harmonic Distortion < 3% THD (Linear Load)
< 6% THD (Non-linear Load)
Transfer Time - AC Mode to Battery Mode 0ms
Transfer Time - Inverter to Bypass 0ms
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode ≥ 94%
Battery Mode ≥ 92%
Battery - Standard Model
Battery Type 12V9AH
Quantity 20
Typical Recharge Time 7 Hours recover to 90% capacity
Charging Current (max.) 1A - 4A (Adjustable)
Charging Voltage 273.0 VDC ± 1%
Battery - Extended Runtime Model
Battery Capacity Depending on the capacity of external batteries
Quantity 16-20
Charging Current (max.) 2A – 12A (Adjustable)
Charging Voltage (13.65 x battery number) Vdc ±1%

Technical specifications are subject to change without notice.