Preloader
Cronus Pro Series
Cost-effective Double Conversion Online UPS 1KVA - 10KVA
Cronus pro Series
Features

Features

  • True double-conversion sine wave UPS
  • Microprocessor control optimizes reliability
  • Input power factor correction
  • Output power factor 0.8
  • Wide input voltage (80V - 300V)
  • Multifunction LCD display allows easy monitoring and control of UPS parameters
  • ECO mode and high efficiency power conversion for energy saving
  • HID (Human Interface Devices) USB Port
  • Bundle Power Management Software with Cloud Monitoring Enable
  • Smart slot for optional Mini-wifi CMCARD-CW, Mini-ETH CMCARD-E, SNMP CARD
  • Generator compatible
Cronus Pro 1K/KS
Capacity (VA/W) 1000VA / 900W
Input
Input Voltage Range 80 VAC-300 VAC ± 3% @ 50% load
160-300 VAC for 1K & 2K @ 100% load
190-300 VAC for 3KVA & Above
Frequency Range 40Hz ~ 70Hz
Power Factor > 0.99
Output
Output Voltage 208 / 220 / 230 / 240 VAC ± 1%
Frequency Range (Battery mode) 50Hz ± 0.5%
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 5% THD (Non-linear Load)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 88%
Battery Mode 85%
ECO Mode 96%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 2
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.5A
Charging Voltage 27.4 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on Battery AH
Quantity 2
Charging Current (max.) 4A/8A
Charging Voltage 27.4 VDC ± 1%
Cronus Pro 2K/KS
Capacity (VA/W) 2000VA / 1800W
Input
Input Voltage Range 80 VAC-300 VAC ± 3% @ 50% load
160-300 VAC for 1K & 2K @ 100% load
190-300 VAC for 3KVA & Above
Frequency Range 40Hz ~ 70Hz
Power Factor > 0.99
Output
Output Voltage 208 / 220 / 230 / 240 VAC ± 1%
Frequency Range (Battery mode) 50Hz ± 0.5%
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 5% THD (Non-linear Load)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 90%
Battery Mode 87%
ECO Mode 96%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 4
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.5A
Charging Voltage 54.7 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on Battery AH
Quantity 4
Charging Current (max.) 4A/8A
Charging Voltage 54.7 VDC ± 1%
Cronus Pro 3K/KS
Capacity (VA/W) 3000VA / 2700W
Input
Input Voltage Range 80 VAC-300 VAC ± 3% @ 50% load
160-300 VAC for 1K & 2K @ 100% load
190-300 VAC for 3KVA & Above
Frequency Range 40Hz ~ 70Hz
Power Factor > 0.99
Output
Output Voltage 208/220/230/240 VAC ± 1%
Frequency Range (Battery mode) 50Hz ± 0.5%
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 5% THD (Non-linear Load)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 91%
Battery Mode 88%
ECO Mode 96%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 6
Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.5A
Charging Voltage 82.2 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on Battery AH
Quantity 6
Charging Current (max.) 4A/8A
Charging Voltage 82.2 VDC ± 1%
Cronus Pro 6K/KS
Capacity (VA/W) 6000VA / 5400W
Input
Input Voltage Range 80 VAC-300 VAC ± 3% @ 40% load
176-300 @ 100% load
Frequency Range 45-55Hz or 54-66Hz
Power Factor > 0.99
Output
Output Voltage 208 / 220 / 230 / 240 VAC ± 1%
Frequency Range (Battery mode) 50Hz ± 0.5%
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 5% THD (Non-linear Load)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 92%
Battery Mode 90%
ECO Mode 96%
Battery - Standard Model
Battery Type 12V 7AH
Quantity 16
Typical Recharge Time 5 hours recover to 90% capacity
Charging Current (max.) 1.0A
Charging Voltage 218.4 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on Battery AH
Quantity 16
Charging Current (max.) 4A
Charging Voltage 218.4 VDC ± 1%
Cronus Pro 10K/KS
Capacity (VA/W) 10KVA / 9KW
Input
Input Voltage Range 80 VAC-300 VAC ± 3% @ 40% load
176-300 @ 100% load
Frequency Range 45-55Hz or 54-66Hz
Power Factor > 0.99
Output
Output Voltage 208/220/230/240 VAC ± 1%
Frequency Range (Battery mode) 50Hz ± 0.5%
Current Crest Ratio 3:1
Harmonic Distortion < 2% THD (Linear Load)
< 5% THD (Non-linear Load)
Waveform (Battery mode) Pure Sinewave
Efficiency
AC Mode 92%
Battery Mode 90%
ECO Mode 96%
Battery - Standard Model
Battery Type 12V 9AH
Quantity 16
Typical Recharge Time 6 hours recover to 90% capacity
Charging Current (max.) 1.0A
Charging Voltage 218.4 VDC ± 1%
Battery - Extended Runtime Model
Battery Type Depending on Battery AH
Quantity 16
Charging Current (max.) 4A
Charging Voltage 218.4 VDC ± 1%

Technical specifications are subject to change without notice.